CRAC Units for Data Centers

Cooltechx manufactures computer room air conditioners, including room-based CRAC and in-row equipment for defined IT loads and airflow designs.

CRAC Units & Related Air-Cooling Equipment

All products

Need help?

Don't hesitate to contact us

CTACJ-CRA in-row precision air conditioner
In-Row Air Conditioner – CTACJ-CRA
CTACJ-CMA room-based air-cooled precision air conditioner
Room-Based Precision Air Conditioner Series – CTACJ-CMA
CTACJ-HEX precision air conditioner for data centers
12.5kW Precision Air Conditioner – CTACJ-HEX130
CTACJ-HEX precision air conditioner for data centers
20kW Precision Air Conditioner – CTACJ-HEX200
CTACJ-HEX precision air conditioner for data centers
30.1kW Room-Based Precision Air Conditioner – CTACJ-CMA3030
CTACJ-HEX precision air conditioner for data centers
40.1kW Room-Based Precision Air Conditioner – CTACJ-CMA3040
CTACJ-HEX precision air conditioner for data centers
50.1kW Room-Based Precision Air Conditioner – CTACJ-CMA3050
CTACJ-HEX precision air conditioner for data centers
7.5kW Precision Air Conditioner – CTACJ-HEX080
CTACJ-HEX precision air conditioner for data centers
Precision Air Conditioner Series – CTACJ-HEX
CTACS0-LING data center cooling equipment
CTACS0-LING
Single-row micro-module data center
600 Single-Row Micro-Module Data Center
PHU integrated energy-saving air conditioning system
PHU Integrated Air Conditioner for Data Centers

CRAC vs CRAH: Choose the Cooling Interface

Selection areaCRAC / direct expansionCRAH / chilled water
Cooling circuitCRAC commonly uses a compressor-based direct-expansion refrigerant circuit.CRAH uses a chilled-water coil supplied by a facility cooling system.
Site interfaceConfirm refrigerant piping, condenser or heat-rejection arrangement and power.Confirm chilled-water temperatures, flow, pressure and water connections.
Air distributionCoordinate room supply and return paths or the defined row-level arrangement.Coordinate the same air-side load and airflow requirements with the water-side design.
Equipment selectionUse sensible heat load, rating conditions, controls and service clearances.Use the air-side duty together with the facility-water operating conditions.

CRAC Unit Selection Guide

Compare CRAC suppliers by sensible capacity, site conditions and installation.

Project input checklist

01. Choose Room-Based or In-Row Cooling

Room-based CRAC serves a defined room air-distribution design. In-row air conditioning targets a row-level air path. Match the equipment location to the rack layout, containment and actual heat-load distribution.

02. Compare Sensible Capacity at the Design Point

Specify the sensible heat load, return-air and target supply conditions, site ambient and operating duty. Compare model performance at compatible test conditions rather than nominal kW alone.

03. Coordinate Installation, Controls & Service

Confirm power, heat-rejection connections, air clearances, BMS signals, condensate and maintenance access. Agree standby and operating strategy with the data-center designer.

Data Center Air-Cooling Resources

Review room-level precision air conditioning against the IT-room layout, airflow and integration scope.

Understand the boundary between facility cooling and the IT-side coolant loop.

CRAC Unit FAQs

Practical answers before equipment selection.

CRAC stands for computer room air conditioner. It describes equipment used to condition air for IT spaces; compressor-based direct-expansion systems are commonly described as CRAC units.

Precision air conditioning is a broader product description. A compressor-based computer-room unit may be described using both terms. Check the cooling circuit, application and exact product specification.

CRAC commonly refers to direct-expansion refrigeration equipment. A CRAH uses a chilled-water coil and depends on the facility water system. The project utilities and cooling architecture determine the appropriate interface.

Use the IT heat-load distribution, rack arrangement, containment, air paths and service access. In-row describes the installation arrangement; confirm whether its cooling circuit is DX or chilled water for the selected model.

Start with the IT sensible heat load and operating conditions, then review air distribution, future load, site ambient, heat rejection and the project resilience strategy. Room floor area alone is insufficient.

Humidity control, humidification and reheat are model- and configuration-specific. State the required temperature and humidity limits and confirm the proposed functions.

The current catalogue includes room-based and in-row air-conditioning equipment as well as related data-center items. Check each product page for its exact equipment scope and cooling circuit.

For a CRAC quotation or OEM configuration review, send the IT load, room and rack layout, supply and return conditions, outdoor design conditions, power, heat-rejection interface, BMS requirements and service constraints. Custom functions must be confirmed for the proposed model.