40.1kw-Room-Based-Precision-Air -Conditioner-CTACJ-CMA3040

40.1kW Room-Based Compressor gas pressurization Air-cooled Precision Air Conditioner Efficiency Reliable Intelligent Control

Product Highlights:

The CMA room-based air-cooled precision air conditioning unit is the most versatile product in the CTACS series. It offers high-efficiency cooling capabilities, a wide power supply tolerance of ±15%, multiple intelligent monitoring and protection features, and a modular, quick-installation design. With 100% front-facing maintenance, it is specifically designed for various IDC data centers, communication rooms, equipment rooms, and other application environments. This unit provides precise temperature and humidity control, fully meeting the heat dissipation needs of medium and low-density data centers.

GLOBAL PARTNERSHIP

Establish Intimidate Partnerships with International Companies
tesla
LG
Alibaba
Hisense
Haier
China unicom
China moblie
electro design
entel
tower
JAZAACO
Sieyuan
telkos
cnet industrial

Why Cooltechx?

Distinguished R&D Staff, Supportive After-sale Service, and Specialized Customization
Technology Leadership, Reliable Quality: Utilizing the latest technology to ensure industry-leading product performance and efficiency.
Customized Solutions: Providing tailored services to meet specific environments and needs.
Energy Efficiency and Environmental Protection: Product design emphasizes energy efficiency and environmental protection, reducing energy consumption and lowering costs.
Professional Support: Technical support and consulting services provided by industry experts.
One-Stop Service: Offering end-to-end service from selection to maintenance, ensuring a seamless experience.
R&D Investment: Continuous investment in R&D to maintain technological leadership and launch new products.

Product features

·  Full inverter design boosts energy efficiency by 25%

·  Low-pressure technology improves seasonal efficiency by 17%

·  Membrane humidifier saves up to 95% in humidification energy

·  Computer room temperature fluctuates less than ±2℃

·  Centralized outdoor unit reduces footprint by 50%

·  Indoor unit allows full front maintenance

·  Graphical display of unit operation status

·  Real-time monitoring and display of fault alarms

·  Group-level optimizatio

Cabinet Air Conditioner Display

Technical parameter

Product Model CTACJ-CMF3040
Cooling Capacity (kW) 40.1
Sensible Cooling Capacity (kW) 36.1
System Type Single System
Refrigerant Type R410A
Heating Method PTC Electric Heating
Heating Capacity (kW) 9
Humidification Method Wet Film Humidification
Humidification Capacity (kg/h) 6
Indoor Unit Parameters
Indoor Unit, Width (mm) 930
Indoor Unit, Depth (mm) 996
Indoor Unit, Height (mm) 1995
Centralized Outdoor Unit Parameters
Outdoor Unit, Width (mm) 1280
Outdoor Unit, Depth (mm) 1100
Outdoor Unit, Height (mm) 2128
Operating Conditions: Indoor return air dry – bulb temperature 24°C, wet – bulb temperature 17°C, outdoor dry – bulb temperature 35°C

 

Flat-type ODU Fan QTY Circuit Net weight(kg) Dimension(mm)(W×D×H)
CMT055SPS3A 1 1 145 817×1200×1216
CMT066SPS3A 2 1 168 817×2225×1048
CMT088SPS3A 2 1 245 817×2225×1216
CMT099SPS3A 2 1 270 817×2225×1216

 

V-type ODU Fan QTY Circuit Net weight(kg) Dimension(mm)(W×D×H)
CMT055SP – C3A 1 1 170 1280×1100×2085
CMT066SP – C3A 1 1 195 1280×1100×2128
CMT088SP – C3A 1 1 210 1280×1100×2128
CMT099SP – C3A 1 1 225 1300×1200×2200

Factory scene

Self-owned industrial air-conditioning production factory:

● Customized Integrated Solutions

● 8-Step Quality Inspection Process

● Manual Quality Inspection

● In-House Testing Laboratory

Ensuring 100% quality inspection of every machine before delivery.

Product features

Applications

Embark on the New Journey With Cooltechx

Big Data Processing

High Performance Computing

Server Room

Why Is Temperature Control Important for Machine Running?

Boost Efficiency and Improve Productivity
The service life of electronic components is directly related to the ambient temperature. Generally, electronic components will have a shorter service life for every 10 degrees higher than the normal indoor temperature.
For High temperature environment:
As a result, the operation efficiency of the equipment will decrease and abnormal operation will occur, and the characteristics of the rubber material will also change.
For low temperature environment:
Below the dew point temperature will cause condensation on the surface of the equipment, increasing the risk of equipment corrosion and abnormal operation of the equipment.
Enhance the service life of electronic components and contribute to the efficiency of the enterprise!

Cooltec Advantage

Unveil the New Stage of Higher Efficiency
1
Professional Staff

Cooltechx is a brand integrating R&D, manufacturing, sales, and service. Our staff comes from Fortune 500 companies with more than 20 years of experience in the air-conditioning industry.

2
OEM & ODM

Our R&D technical teams can support customization, which means that if you have different requirements, higher standards, or more functional needs, we will give you the most cost-effective  cooling solution.

3
Sample Avaiable

Cooltechx cabinet air conditioner sample is available, ordering any amount of product is welcomed. The sample is of good quality at a reasonable price.

Technical & Service Team Support

Reliable R&D and After-sales Team Team
Professional Technical Team
Our technical team will guide and support you from purchase to maintenance. For oversea customers offer video conference for product introduction and guidance according your time.
Guidance Maintenance Team
There will be a professional after-sales team to follow up, and regularly provide professional advice on cleaning, maintenance. If you have any problems with the products or after sales, you can contact our after sales team at the first time, and they will give professional advice at the first time.
After-sales Team
First-class after-sales service, to provide end customers with full technical protection, empowering dealers to provide technical training, website construction, market development ,and promotional support.
If there are defective or incorrectly shipped goods, please contact us within 5 days of receiving the goods.

Certificate Authentication

Professional Certification Endorsement Provided

FAQ

Through advanced sensing technology and control systems, temperature accuracy of ±0.5°C and humidity control of ±3% RH can be achieved, ensuring optimal operating conditions for data center equipment.

Utilizes high-efficiency components such as variable frequency compressors and EC fans, combined with intelligent control systems that automatically adjust output based on actual load, effectively reducing energy consumption.

Redundancy design and fault warning systems are typically implemented to enhance overall system reliability and availability.

The design considers the year-round cooling needs of data centers, even during winter. Equipment, pipelines, and valves are equipped with effective measures to prevent freezing or cold air from directly entering the main server room, which could lead to condensation and negatively impact electronic information equipment.

The design is simple and easy to maintain, while energy-saving technologies reduce operational costs. For instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.

For high-density IT cabinets, high heat density solutions are provided to effectively address localized hotspots, including regional high heat density strategies and localized hotspot mitigation methods. instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.