The CMA room-based air-cooled precision air conditioning unit is the most versatile product in the CTACS series. It offers high-efficiency cooling capabilities, a wide power supply tolerance of ±15%, multiple intelligent monitoring and protection features, and a modular, quick-installation design. With 100% front-facing maintenance, it is specifically designed for various IDC data centers, communication rooms, equipment rooms, and other application environments. This unit provides precise temperature and humidity control, fully meeting the heat dissipation needs of medium and low-density data centers.
· Full inverter design boosts energy efficiency by 25%
· Low-pressure technology improves seasonal efficiency by 17%
· Membrane humidifier saves up to 95% in humidification energy
· Computer room temperature fluctuates less than ±2℃
· Centralized outdoor unit reduces footprint by 50%
· Indoor unit allows full front maintenance
· Graphical display of unit operation status
· Real-time monitoring and display of fault alarms
· Group-level optimizatio
Product Model | CTACJ-CMF3040 |
Cooling Capacity (kW) | 40.1 |
Sensible Cooling Capacity (kW) | 36.1 |
System Type | Single System |
Refrigerant Type | R410A |
Heating Method | PTC Electric Heating |
Heating Capacity (kW) | 9 |
Humidification Method | Wet Film Humidification |
Humidification Capacity (kg/h) | 6 |
Indoor Unit Parameters | |
Indoor Unit, Width (mm) | 930 |
Indoor Unit, Depth (mm) | 996 |
Indoor Unit, Height (mm) | 1995 |
Centralized Outdoor Unit Parameters | |
Outdoor Unit, Width (mm) | 1280 |
Outdoor Unit, Depth (mm) | 1100 |
Outdoor Unit, Height (mm) | 2128 |
Operating Conditions: | Indoor return air dry – bulb temperature 24°C, wet – bulb temperature 17°C, outdoor dry – bulb temperature 35°C |
Flat-type ODU | Fan QTY | Circuit | Net weight(kg) | Dimension(mm)(W×D×H) |
CMT055SPS3A | 1 | 1 | 145 | 817×1200×1216 |
CMT066SPS3A | 2 | 1 | 168 | 817×2225×1048 |
CMT088SPS3A | 2 | 1 | 245 | 817×2225×1216 |
CMT099SPS3A | 2 | 1 | 270 | 817×2225×1216 |
V-type ODU | Fan QTY | Circuit | Net weight(kg) | Dimension(mm)(W×D×H) |
CMT055SP – C3A | 1 | 1 | 170 | 1280×1100×2085 |
CMT066SP – C3A | 1 | 1 | 195 | 1280×1100×2128 |
CMT088SP – C3A | 1 | 1 | 210 | 1280×1100×2128 |
CMT099SP – C3A | 1 | 1 | 225 | 1300×1200×2200 |
Self-owned industrial air-conditioning production factory:
● Customized Integrated Solutions
● 8-Step Quality Inspection Process
● Manual Quality Inspection
● In-House Testing Laboratory
Ensuring 100% quality inspection of every machine before delivery.
Cooltechx is a brand integrating R&D, manufacturing, sales, and service. Our staff comes from Fortune 500 companies with more than 20 years of experience in the air-conditioning industry.
Our R&D technical teams can support customization, which means that if you have different requirements, higher standards, or more functional needs, we will give you the most cost-effective cooling solution.
Cooltechx cabinet air conditioner sample is available, ordering any amount of product is welcomed. The sample is of good quality at a reasonable price.
Through advanced sensing technology and control systems, temperature accuracy of ±0.5°C and humidity control of ±3% RH can be achieved, ensuring optimal operating conditions for data center equipment.
Utilizes high-efficiency components such as variable frequency compressors and EC fans, combined with intelligent control systems that automatically adjust output based on actual load, effectively reducing energy consumption.
Redundancy design and fault warning systems are typically implemented to enhance overall system reliability and availability.
The design considers the year-round cooling needs of data centers, even during winter. Equipment, pipelines, and valves are equipped with effective measures to prevent freezing or cold air from directly entering the main server room, which could lead to condensation and negatively impact electronic information equipment.
The design is simple and easy to maintain, while energy-saving technologies reduce operational costs. For instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.
For high-density IT cabinets, high heat density solutions are provided to effectively address localized hotspots, including regional high heat density strategies and localized hotspot mitigation methods. instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.